Customer Case | How Do You Choose a Control Cabinet PC?
2026-10-12
Table of Contents
- I. Introduction
- II. Aligning PC Configuration with the Cabinet Integration Plan
- III. Matching the Mounting Method to the Electrical Panel
- IV. Checking Storage Capacity Against Physical Drive Fit
- V. Confirming Mounting, Space and Storage Before Finalizing a Cabinet PC
Introduction
Introduction
Integrating a control cabinet PC requires agreement between the computer configuration and the cabinet layout. The mounting method, space occupied by the assembly, and physical fit of the storage drives all need to work together. A compact enclosure is one part of that decision.
An industrial machine vision company encountered these questions while preparing an electrical cabinet. Its team needed secure PC mounting and separate drives for the operating system, applications and project data. The resulting configuration decisions illustrate how to connect cabinet planning with the selection of a compact industrial PC.
Aligning PC Configuration with the Cabinet Integration Plan
Aligning PC Configuration with the Cabinet Integration Plan
Aligning PC Configuration with the Cabinet Integration Plan
Aligning PC Configuration with the Cabinet Integration Plan
Aligning PC Configuration with the Cabinet Integration Plan
Aligning PC Configuration with the Cabinet Integration Plan
Aligning PC Configuration with the Cabinet Integration Plan
Aligning PC Configuration with the Cabinet Integration Plan
Aligning PC Configuration with the Cabinet Integration Plan
The customer's cabinet project combined two requirements: selecting the computer's hardware and defining how it would fit into the electrical panel. The team requested 32GB of memory, four 2.5GbE Ethernet ports and two USB 3.1 ports. It also specified separate storage roles: a primary SSD for the operating system and applications, plus a secondary HDD for data.
The selected SIN-3094-H610E industrial PC provided a platform with M.2 NVMe storage and a separate 2.5-inch HDD/SSD tray. This arrangement supported the requested two-drive configuration. The customer chose an Intel Core i7-13700 processor, while the cabinet integration discussion focused on mounting and space allocation.
The layout work required a description of the physical assembly as well as a hardware specification. The customer requested a datasheet and a 3D CAD model to finalize the cabinet layout; SINSMART supplied technical parameters and an installation dimension diagram. For a similar project, the mechanical drawing and configuration list should describe the same assembly, including its mounting hardware and external accessories.
Matching the Mounting Method to the Electrical Panel
Matching the Mounting Method to the Electrical Panel
Matching the Mounting Method to the Electrical Panel
Matching the Mounting Method to the Electrical Panel
Matching the Mounting Method to the Electrical Panel
Matching the Mounting Method to the Electrical Panel
The customer initially asked about an industrial PC DIN rail mount, then requested another way to fix the computer securely inside the electrical panel. SINSMART proposed the standard wall-mount bracket included with the PC. The customer confirmed that this bracket was suitable for the intended fixing arrangement.
This choice separated the installation requirement from the accessory first requested. Secure attachment to the electrical panel was the requirement; the included bracket was the mounting option the customer accepted. For another cabinet, a wall-mount bracket is a candidate when the intended fixing surface and hole arrangement can accommodate it.
Space planning should follow that mounting choice. The SIN-3094-H610E's published enclosure dimensions are 212 × 165 × 63 mm, but the project configuration also included a Fan Kit. When preparing a cabinet layout, request the dimensions of the assembly with the selected bracket and fan accessory, then allocate space for connections and access. Use the enclosure dimensions as a starting reference, with the configured assembly drawing governing the installation layout.

Checking Storage Capacity Against Physical Drive Fit
Checking Storage Capacity Against Physical Drive Fit
Checking Storage Capacity Against Physical Drive Fit
Checking Storage Capacity Against Physical Drive Fit
Checking Storage Capacity Against Physical Drive Fit
Checking Storage Capacity Against Physical Drive Fit
Checking Storage Capacity Against Physical Drive Fit
Checking Storage Capacity Against Physical Drive Fit
The storage decision required both a capacity choice and a mechanical compatibility check. The customer initially requested a 4TB secondary HDD. For this project's drive bay, the secondary drive had to meet a maximum thickness of 7 mm. The customer accepted a 2TB HDD meeting that condition, paired with a 1TB NVMe SSD in the final configuration.
The two drives retained distinct intended roles while the secondary capacity changed. The NVMe SSD addressed the system-and-application storage requirement, and the HDD addressed the separate data-storage requirement. The accepted 2TB capacity was a project-specific choice, rather than a general capacity recommendation for machine vision systems.
SINSMART also offered SSD alternatives during the storage discussion. For a similar configuration, establish whether data capacity or drive technology can change before selecting an alternative. If capacity is fixed, evaluate a compatible drive that preserves it. If a smaller HDD is acceptable, confirm that capacity explicitly alongside the drive's physical dimensions.
|
Storage decision
|
Agreed project configuration
|
Meaning for a similar selection
|
|---|---|---|
|
System and application drive
|
1TB NVMe SSD
|
Define the system-drive role separately from data capacity.
|
|
Separate data drive
|
2TB HDD
|
Confirm the usable capacity required for the planned data workload.
|
|
Secondary-drive thickness
|
7 mm
|
Check the exact drive's dimensions against the intended bay.
|
Confirming Mounting, Space and Storage Before Finalizing a Cabinet PC
Confirming Mounting, Space and Storage Before Finalizing a Cabinet PC
Confirming Mounting, Space and Storage Before Finalizing a Cabinet PC
Confirming Mounting, Space and Storage Before Finalizing a Cabinet PC
Confirming Mounting, Space and Storage Before Finalizing a Cabinet PC
Confirming Mounting, Space and Storage Before Finalizing a Cabinet PC
Confirming Mounting, Space and Storage Before Finalizing a Cabinet PC
The final configuration combined the SIN-3094-H610E with an i7-13700 processor, 32GB DDR4 memory, a 1TB NVMe SSD, a 2TB HDD and a Fan Kit. The customer's acceptance of the wall-mount bracket and the 7 mm HDD established specific mounting and storage choices for the cabinet plan.
For a cabinet project with similar requirements, bring the following information into one configuration review:
-
Mounting arrangement: identify the fixing surface, selected bracket and attachment points.
-
Assembly dimensions: obtain the drawing for the PC with the selected external accessories and check it against the allocated cabinet space.
-
Storage requirements: state the purpose and required capacity of each drive, then confirm the secondary drive's thickness and bay compatibility.
-
Configuration agreement: confirm the accepted capacities and accessories together with the processor, memory and required interfaces.
The reusable decision is to confirm the complete assembly and storage arrangement together. That gives the cabinet layout and the hardware configuration a common reference before installation planning proceeds.
To discuss a similar requirement, contact SINSMART about a cabinet PC configuration with the available mounting space, preferred fixing method, interface list and separate system/data storage requirements.

LET'S TALK ABOUT YOUR PROJECTS
- sinsmarttech@gmail.com
-
3F, Block A, Future Research & Innovation Park, Yuhang District, Hangzhou, Zhejiang, China
Our experts will solve them in no time.

Rackmount PC
Embedded Computing
Industrial Portable Computers
Rugged Tablets
Rugged Laptop
Industrial Panel PC
Rugged Handheld
Advantech Industrial PC